This Traulsen unit is built to our highest quality standards. We build our refrigerators and freezers this way as a matter of
pride. This philosophy has made Traulsen the leader in commercial refrigeration since 1938. We thank you for your choice
and condence in Traulsen equipment and we know you will receive many years of utility from this equipment.
All Traulsen units are placed on a permanent record le with the service department. In the event of any future ques-
tions you may have, please refer to the model and serial number found on the name tag a󰮐xed to the unit. Should
you need service, call us on our toll free number, 800-825-8220 between 7:30 am - 4:30 pm CST, Monday thru Friday.
You may also log onto www.traulsen.com for further information. It is our pleasure to help and assist you in every
possible way.
OWNER’S MANUAL
Instructions for the installation, operation
and maintenance of Traulsen:
FORM NUMBER TR35745 REV. 1/08 P/N 375-60297-00
Quality Refrigeration
INSTALLER
COMPLETE THE FOLLOWING INFORMATION PRIOR TO UNIT INSTALLATION
INITIAL START DATE: SERIAL NO.
MODEL TYPE:
COMPANY/INDIVIDUAL NAME:
INSTALLER:
TU Series Full-Size Undercounter Refrigerators
TU044HT, TU072HT & TU100HT
TU Series Full-Size Undercounter Freezers
TU044LT & TU072LT
Page view 0
1 2 3 4 5 6 ... 23 24

Summary of Contents

Page 1 - OWNER’S MANUAL

This Traulsen unit is built to our highest quality standards. We build our refrigerators and freezers this way as a matter of pride. This philosophy

Page 2 - I. THE SERIAL TAG

VII. g - ADJUSTING THERMOSTAT SET POINT HIGH:This parameter sets the high point of the desired cabinet temperature range. Typically, freezers will ran

Page 3 - III. INSTALLATION (continued)

VII. h - ADJUSTING THERMOSTAT SET POINT LOW:This parameter sets the low point of the desired cabinet temperature range. Typically, freezers will range

Page 4 - V. CARE & MAINTENANCE

VII. MICROPROCESSOR CONTROL (continued)-11-VII. j - SETTING THE 24-HOUR CLOCK:The internal time clock must be set in order for the data storage memory

Page 5 - DRAWERS:

VII. MICROPROCESSOR CONTROL (continued)-12-VII. k - SETTING THE DATE:The date must be set in order for the data storage memory to correctly log events

Page 6 - VII. MICROPROCESSOR CONTROL

This parameter allows a service technician to start a defrost cycle at any time. This parameter will override any lock-out settings. Follow the instr

Page 7 - VII. b - ALARM EXPLANATIONS:

The defrost lockout parameters allow the customer to prevent the unit from going into a defrost cycle for two hours during a set time frame. Customers

Page 8 - VII. d - NOTES TO THE USER:

VII. p - ADJUSTING THE ROOM TEMPERATURE OFFSET:The room temperature o󰮏set parameter allows a service technician or end user the ability to have the di

Page 9

VII. r - VIEWING SENSOR TEMPERATURES:These parameters allow a service technician or customer to view the temperature of all sensors within the unit.

Page 10

-17-VIII. WIRING DIAGRAMNote: Refer to the wiring diagram below (applies to refrigerators and freezers units) for any service work performed by a qu

Page 11 -

PROBLEM POSSIBLE SOLUTION1. Condensing unit fails to start. a. Check if cord & plug has

Page 12

TABLE OF CONTENTSThe serial tag is a permanently a󰮐xed label on which is recorded vital electrical and refrigeration data about your Traulsen product,

Page 13 -

-19-X. SERVICE ASSISTANCEX. a - SERVICE INFORMATION:Before calling for service, please check the following: Is the electrical cord plugged in? I

Page 14

XI. WARRANTIESSTANDARD DOMESTIC WARRANTYTRAULSEN & CO., INC. warrants new equipment to the original purchaser, when installed within the United S

Page 15

-21-XII. SERVICE PARTS LISTITEM DESCRIPTION PART NUMBERCASTER ALL MODELS6” ADJUSTABLE CASTER NO LOCK SER-60538-006” ADJUSTABLE CASTER WITH LOCK SER-60

Page 16

NOTES:

Page 17

HOURS OF OPERATION:Monday thru Friday 7:30 am - 4:30 pm CSTQuality Refrigeration© 2008 Traulsen - All Rights ReservedTraulsen4401 Blue Moud Road Fort

Page 18 - VIII. WIRING DIAGRAM

-2-II. RECEIPT INSPECTIONAll Traulsen products are factory tested for performance and are free from defects when shipped. The utmost care has been ta

Page 19 - IX. TROUBLE SHOOTING GUIDE

IV. a - REFRIGERATORS:Both refrigerators and Freezers do not require manual defrosting. During normal operation, a refrigerator con-tinuously circu

Page 20 - X. SERVICE ASSISTANCE

-4-V. b - REPLACING THE GASKETS:To remove the gasket to be replaced, grasp it rmly by one corner and pull it out. Before attempting to install a ne

Page 21 - XI. WARRANTIES

-5-VII. MICROPROCESSOR CONTROLYour new refrigerator or freezer cabinet is equipped with a state-of-the-art microprocessor control, which precisely re

Page 22 - XII. SERVICE PARTS LIST

-6-High Cabinet Air Temperature: The audible alarm will sound and the display will read HI CAb when the temperature inside the cabinet rises

Page 23

-7-VII. MICROPROCESSOR CONTROL (continued)VII. c - CONTROL PANEL DIAGRAM:VII. d - NOTES TO THE USER:You only have 20-30 seconds between button pushes.

Page 24 - Traulsen

VII. e - ENTER THE SERVICE ACCESS: Use the security code 0, A, 1 and the following instructions:Press the set button .